Part Number Hot Search : 
ASI10467 AQV210 COLTD CZRC5370 5KE120A PM5346 2512MR 6033C
Product Description
Full Text Search
 

To Download FAA08DM24 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Timers Delay on Operate Types FAA01, FAA08
* * * * Time range 0.05 s to 300 h Knob selection of time range Knob adjustable time setting Knob selection of operating mode (4 functions): A - delay on operate B2 - symmetrical recycler ON first E - interval J - one shot Automatic start Repeatability: 0.3% on full scale Output: 5 A DPDT relay 48 x 48 mm housing for front panel mounting 8 or 11 pin sockets LED indication for relay status and power supply ON
* * * * * *
Product Description
Delay on operate timer with 4 functions and selectable time ranges from 0.05 seconds to 300 hours. Housing 48 x 48 mm for front panel mounting and on 8-pin or 11-pin socket.
Ordering Key
Housing Function Type Item number Output Power supply
FAA 01 D M24
Type Selection
Mounting Front or socket Front or socket Output DPDT DPDT Plug 11-pin 8-pin Supply: 100 to 240 VAC FAA01DM24 FAA08DM24
Time Specifications
Time ranges Selectable by front knob Time unit 1.2 Full scale setting 3 12 30 Repeatability Setting accuracy Voltage drift sec min 0.05 to 1.2 0.125 to 3 0.5 to 12 1.25 to 30 hrs 10h 0.5 to 12 1.25 to 3 5 to 120 12.5 to 300
Output Specifications
Output Output insulation resistance Contact Ratings (AgCdO12) Resistive loads AC 1 Mechanical life Electrical life DPDT relay > 100 M (at 500 VDC) 5 A @ 250 VAC / 30 VDC 1 x 107 operations 1 x 105 operations (5 A at 250 VAC, cos = 1, 1.8 x 103 operations/h) < 1800 operations/h
Temperature drift
0.3% on full scale (10 ms max in the range of 1.2 s) 5% on full scale 50 ms 0.5% on full scale (10 ms max in the range of 1.2 s) 2% on full scale (10 ms in the range of 1.2 s) >100 ms >50 ms
Operating frequency
Supply Specifications
Power Supply Rated operational voltage throuhgt terminals: (FAA01DM24) 2, 10 (FAA08DM24) 2, 7 Overvoltage cat II (IEC 60947-1) 100 to 240 VAC +10%-15% 50 / 60 Hz 100 to 240 VAC +10%-15% 50 / 60 Hz 10VA @ 240 VAC, (50 Hz)
Reset Power supply interruption Pulse width
Power consumption Rated operational power
Specifications are subject to change without notice (26.07.05)
1
FAA01, FAA08
General Specifications
Indication for Power supply On Output ON Environment Degree of protection Operating temperature Ambient humidity Housing dimesions Weight CE marking EMC Immunity Emission LED, green (flashing when timing) LED, red IP 40 (front panel) -10 to +55 C (14 to 131 F) 35 to 85% RH 48 x 48 mm Approx. 95 g Yes Electromagnetic Compatibillity According to EN 61000-6-1 According to EN 61000-6-3
Function and Time Setting
Upper right knob: Setting of function A - delay on operate B2 - simmetrical recycler E - interval J - one shot Lower right knob: Time unit selector sec (seconds) min (minuts) hrs (hours) 10h (10 hours) Lower left knob: Time range selector 1.2, 3, 12 and 30 Centre knob: Time setting on relative scale
Mode of Operation
Function A Delay on operate The set delay period begins as soon as the power supply is connected. At the end of the set delay the relay operates and doesn't release until the power supply is interrupted for at least 100 ms. Function B2 Symmetrical recycler (ON first) The relay operates and the time period start as soon as the power is applied. At the end of the first set time period, the relay releases. At the end of the second time period (equal to the first), the relay operates again. This sequence continues with equal ON- and OFF- time periods until the power supply is interrupted for at least 100 ms. Function E Interval The relay operates and the time period begins as soon as the power is applied. The relay releases at the end of the time period or when the power supply is disconnected for at least 100 ms. Function J One shot The time period begins as soon as the power supply is connected and at the end of this period the relay operates for 1s.
Range and operation mode selection
Power indicator (green) (Flashes when timer operates; on when timer stops operating) Output indicator (red) (Lit when output is ON)
Operating mode display window Operating mode selector (function A, B2, E, J)
Scale range display windows Time range selector (1.2, 3, 12 and 30 at full scale) Time unit display window Time unit selector (sec, min, hrs, 10h) Time setting knob (set time)
2
Specifications are subject to change without notice (26.07.05)
FAA01, FAA08
Wiring Diagrams
FAA01
L(+) 2 4
m m
FAA08
L(+) 9 2 4 m 3 5 m 6
3
8
10
1
11
7
1
8
N(-)
N(-)
Operating Diagrams
Function A - Delay ON operate Function B2 - Symmetrical Recycler (ON first)
Power supply
Power supply
Relay
T
T
Relay
T
T
T
T
T
LED "POWER"
LED "POWER"
Function E - Interval
Function J - One Shot
Power supply
Power supply
1s0.6s
1s0.6s
T
Relay
T
Relay
T
T
LED "POWER"
LED "POWER"
Dimensions
FAA01 - FAA08
15 15 48 48
9 6
81,6 81.6 60,2 68.2
48 48
39 39
Specifications are subject to change without notice (26.07.05)
3


▲Up To Search▲   

 
Price & Availability of FAA08DM24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X